A string inverter converts the direct current produced by one or more series-connected strings of modules into grid-synchronized alternating current. The SUN2000-5KTL-L1 is a typical single-phase unit for homes: two independent maximum power point trackers (MPPTs) let you split the array across two roof faces with different orientation or tilt without losing yield.
The inverter accepts up to 600 V DC and tracks from about 90 V, so short strings of modern 430–475 W rooftop modules fit easily. A built-in AFCI (arc-fault circuit interrupter) and string-level monitoring through the FusionSolar app add safety and visibility. It is "battery-ready": a compatible high-voltage battery can be connected later without replacing the inverter.
For a typical 5–6.5 kWp villa system, a DC/AC ratio of 1.1–1.3 is common in the GCC, because high cell temperatures reduce real DC output well below the STC rating.
Hybrid inverter for homes with low-voltage LFP batteries: solar, battery, grid and generator inputs with automatic backup switching.

Three-phase hybrid for high-voltage batteries, with full backup on all three phases and 150 % DC oversizing.

Six-MPPT commercial inverter for warehouse, factory and carport rooftops, with smart I-V curve diagnosis.

Commercial hybrid inverter for high-voltage battery cabinets: peak shaving, backup and diesel-generator integration for sites with weak grids.

Nine-MPPT workhorse for large rooftops and distributed ground-mount plants, 98.7 % max efficiency.

300 kW / 330 kVA string inverter for utility-scale plants on 1,500 V DC, feeding an 800 V AC medium-voltage skid.

Megawatt-class central inverter for large, uniform utility plants; available as a turnkey MV skid with transformer and switchgear.

Module-level inverter: each module produces AC independently; suited to shaded or complex roofs and rapid-shutdown compliance.

All-in-one off-grid inverter-charger with built-in MPPT for remote sites, farms, cabins and telecom shelters.