Stepping up to 24 V halves battery current compared with 12 V and makes a 3 kW inverter practical. The kit combines 1.5 kWp of standard framed modules (three to four 400–550 W panels in series), an all-in-one inverter-charger with an integrated MPPT controller (typically 100 A solar charging, up to 450–500 V PV input) and a generator or grid input, plus a 25.6 V 200 Ah LFP battery storing 5.1 kWh.
In Gulf sun the array yields about 6–7 kWh per day, covering a modest load profile — lighting, a full-size fridge, fans, a TV, a small water pump and a 0.75–1 ton inverter air conditioner for a few hours in the evening. The battery gives one night of autonomy for essentials; for cloudy or dusty periods, the inverter can charge from a small generator through its AC input, with automatic switchover.
Sizing check: list each load in watts and hours per day, add 20–25 % for inverter and battery losses, and keep the daily consumption below about 80 % of the expected solar yield in the worst month. Install the battery in a ventilated, shaded enclosure — LFP tolerates heat better than lead-acid, but a cell temperature above 45 °C still shortens its life. Ground the inverter chassis and the array frame, and fit a DC SPD on the PV input in lightning-prone areas.
Wheeled LFP power unit with 3.6 kW inverter, dual MPPT inputs and add-on battery packs up to about 20 kWh: home backup with no installer needed.

ETFE-laminated monocrystalline panel that folds into a briefcase with kickstands. Connects to power stations through an MC4 or XT60 adaptor.

Complete small system for cabins, kiosks, campers and farm huts: 2 × 200 W panels, 30 A MPPT, 12.8 V 100 Ah LFP battery, 1 kW pure-sine inverter, cables and fuses.

Low-cost controller for small 12/24 V systems with panels matched to battery voltage; LCD, USB outputs and selectable lead-acid or lithium profiles.

Tracks the panel's maximum power point and converts excess voltage into charging current. Handles up to 3.2 kW of PV at 48 V, with Bluetooth monitoring and lithium profiles.

Heavy-duty controller for 48 V battery banks up to 5.8 kW of PV, with longer strings, parallel operation and network monitoring for farms, telecom and remote sites.

Charges a vehicle or boat house battery from the alternator and roof panels at the same time, with the correct lithium profile and starter-battery protection.

Transformer-based inverter with 3× surge capacity for motors, pumps and compressors, a built-in battery charger and automatic transfer from grid or generator.

Panel, LFP battery, controller, LED head and motion sensor in one housing for 6–8 m poles. Lights roads, compounds and car parks with no trenching or grid connection.