The I-V curve is the fingerprint of a PV string. By sweeping the string from short circuit to open circuit in a fraction of a second and recording irradiance and cell temperature with a wireless reference sensor, the tracer translates the result to STC and shows whether power, fill factor, Voc and Isc match the datasheet.
Shape deviations reveal specific faults: a step indicates shading or a failed bypass diode, a low slope near Isc points to shunt losses or PID, and a soft knee suggests increased series resistance from corroded connectors. Commissioning per IEC 62446-1 Category 2 and warranty claims both rely on these measurements.
Battery-powered rotating brush on a telescopic pole for rooftops and small plants; optional water connection.

Aerial infrared survey that detects hot spots, failed diodes, disconnected strings and cracked modules across an entire plant in hours.

CAT III 1500 V kit: insulation resistance, Voc, Isc, polarity, earth continuity and DC clamp current for commissioning and fault-finding.

Arc-rated clothing, face shield, insulated gloves and safety footwear for work on live PV DC and LV AC equipment.

Optional nano-coating applied on site that reduces dust adhesion and makes cleaning easier; lasts 1–3 years.

Pair of glass-fibre reinforced spanners for tightening MC4 cable glands and releasing the locking latches without damaging the housing.

Pocket meter reading plane-of-array irradiance in W/m² and module back-sheet temperature — the quick reference for commissioning and performance checks.

Radiometric infrared camera for finding hot cells, failed bypass diodes, loose terminals and overheated fuses in modules, combiner boxes and switchboards.

Measures earth electrode resistance and soil resistivity with stakes, plus stakeless clamp testing of individual rods in a meshed earthing system.