Fans are the main wear part of a forced-air-cooled inverter. When one stops or slows, the inverter first derates, cutting output on the hottest days, and eventually trips on over-temperature. In Gulf conditions, sand and humidity shorten fan life considerably, so replacement every five to seven years is normal on commercial string inverters.
These fans have fully encapsulated motor electronics rated IP68, dual ball bearings for long life at high temperature (typically 50,000+ hours at 40 °C, considerably less at 70 °C), and a four-wire connection with PWM speed control and tachometer feedback, so the inverter can detect a stalled fan. Common sizes are 80, 92, 120 and 172 mm at 12, 24 or 48 V DC.
Replace like for like: same frame size and thickness, voltage, connector and airflow direction, and preferably the same airflow and static pressure figures; a weaker fan will keep the inverter running but at higher component temperature. Clean the heat sink fins at the same time, as packed dust often reduces airflow more than a worn fan does.
Power-stage board carrying the boost and inverter bridges, gate drivers and DC-link capacitors. The major spare most often needed after surge or overheating damage.

Assembled MPPT buck-converter board with automatic 12/24/48 V battery detection, for off-grid controller builds and repairs.

Battery management board for 48 V-class LFP packs with cell monitoring, MOSFET switching, passive balancing and CAN/RS485 inverter communication.

Capacitive or inductive energy-transfer balancer that moves charge between cells continuously, keeping large LFP packs aligned.

Industry-standard 62 mm half-bridge IGBT module with anti-parallel diodes, used in central and large string inverters, PCS and motor drives.

Silicon-carbide half-bridge module for high-frequency, high-efficiency inverters, DC/DC stages and fast chargers.

Self-healing metallised-polypropylene capacitor for inverter DC buses, with high ripple-current rating and long life at elevated temperature.

Sealed, gas-filled DC contactor for battery racks, PCS and high-voltage battery packs, with magnetic arc blow-out and auxiliary contact.

PCB-mount power relay used as the AC output disconnect in string and hybrid inverters, with wide contact gap for grid-code isolation.